6220 Lower York Rd
New Hope, PA 18938
(267)406-6050

Local Reviews
for new britain, pa


Job Locations
for new britain, pa

ryan_57@aol.com

ryan_57@aol.com Job Checkin

Install a metered 48,000 grain Clack water softener w/brine tank and bypass valves Install a GDS 8GPM UV light system with alarm and a 2 x 10 sediment pre filter housing/bracket, wrench and 30 micron inset cartridge. Install a single tank PFAS reduction system with a Clack in/out valve and one (1) cubic foot of RT 110 resin. Clack products have a five year warranty and our workmanship is warranted for 90 days.


Chris G.

Chris G. Job Checkin

Quote for softener and a neutralizer


Chris G.

Chris G. Job Checkin

Constant pressure system conversion Replace existing 2 HP pump with a new 3 Phase 2HP 35 GPM StaRite or similar unit. Replace existing well cable with new 10/3 double jacket flat wire. Replace existing well pipe with new schedule 120 1.25" pipe. Install (1) inline SS check valve. Remove existing well tanks (2) and replace with one 1119 gallon Flexcon pneumatic well tank. Install a Variable frequency Driver, PID20 230V Install an electronic pressure transducer. Install (2) Viuqa UV light systems and (2) 4 x 20 filter housing w/brackets and cartridge inserts Reconfigure plumbing to accommodate the new well tank. Install a 4 x 20 sediment filter Chlorinate the well


Chris G.

Chris G. Job Checkin

Jjjjk


ryan_57@aol.com

ryan_57@aol.com Job Checkin

Looked over well system and took basic water test


Chris G.

Chris G. Job Checkin

Out of water


Chris G.

Chris G. Job Checkin

Convert old jet pump to a submersible pump. Locate and raise well casing in back yard. Install new well tank and remove old tank. Install a 10s05 pump in well along with a new pitiless. Jet Pump to submersible pump conversion - Locate and excavate wellhead. Most excavations are ~3 to 4 feet deep and in rare instances deeper. As work is progressing, we will inform of any issues in this regard and any additional costs. - Raise by adding a welded pipe extension to the 6" steel wellhead casing. For purposes of this estimate 4' to 6' steel casing is added and subject to change. Casing is billed on a linear foot basis. - Install a pitless adapter and vermin proof health department approved well cap. - Install a 1/2HP 2W 230V submersible well pump. For purposes of this estimate we are assuming a pump set depth of 100' and the pipe and wire length may vary. Both are billed on a linear foot basis. - Install a 33 gallon well tank with all associated fittings. - Remove all old equipme


Chris G.

Chris G. Job Checkin

Install of iron breaker in PA


Chris G.

Chris G. Job Checkin

Install up


Chris G.

Chris G. Job Checkin

Replace of well cap in new Britain


Chris G.

Chris G. Job Checkin

Install water tank and iron breaker in new Britain


Chris G.

Chris G. Job Checkin


Chris G.

Chris G. Job Checkin